Examples

Dual-Axis, glass, transparent, and translucent—measure clear or translucent part diameter from two viewpoints, just as accurately as diameter of an opaque part.  The two diameter measurements are coplanar and perpendicular to each other.

With such products, laser light can bleed through the part making it appear to the system that there is more than one part present.  In the illustration, one or two extra segments of light are shown bleeding through the part in each axis.

Systems without proper hardware and software report this condition as an error.  However, all of LaserLinc’s systems include the proper hardware and software, at no charge, so they are able to report accurate measurements and ignore any laser light that may bleed through the product.

Note: any of the measurements shown for dual-axis may be applied to clear and translucent products.

To view other measurements, click on the selections on the left.

These measurement methods can be performed using Total Vu™ software and any of the micrometers that LaserLinc supports.